Skip to product information
1 of 2

Magnaflux

Magnaflux Y-7 AC/DC Yoke - 230V

Magnaflux Y-7 AC/DC Yoke - 230V

SKU: SKU:625644

Stock Status: In stock
Regular price $1,114.00
Regular price $1,353.00 Sale price $1,114.00
Sale Sold out
  • In stock items ship Same Day
  • Authorized Magnaflux Distributor
  • Questions? Call or email
View full details

Magnaflux Y-7 AC/DC Electromagnetic Yoke – 230V

The Magnaflux Y-7 is a durable, high-strength AC/DC electromagnetic yoke designed for surface and sub-surface magnetic particle inspection in the most demanding field and shop environments. Solid-state controls allow the operator to switch between AC for surface indications and DC for sub-surface indications — making the Y-7 the most versatile single yoke in the Magnaflux lineup.

Featuring sealed chemical-resistant construction, articulating legs to contour to any part shape, and a robust strain-relieved 12-foot cord, the Y-7 is ideal for weld inspection and remote field testing. Each yoke carries an individual serial number for full traceability.

Note: Yoke only — for the complete kit including magnetic powders, paint marker, and carrying case, see the Magnaflux Y-7 AC/DC Yoke Kit.

Key Features

  • Dual AC/DC Operation: Switch between AC (surface indications) and DC (sub-surface indications) to meet all inspection requirements with a single tool
  • Sealed Chemical-Resistant Construction: Withstands harsh field environments including MPI chemicals and abrasive contaminants
  • Articulating Legs: Contour to any part shape for reliable magnetic contact on complex geometries
  • Strain-Relieved 12-Foot Cord: Built for rugged field use with extended reach for remote testing
  • Serialized: Individual serial number on each yoke for traceability and calibration records
  • Exceeds ASTM E1444 Lifting Specifications: Certified lifting force for compliant AC and DC MPI inspections
  • Solid-State Controls: Reliable, durable electronics housed internally for maximum safety and longevity
Pro NDT Tip

When to Use AC vs. DC on the Y-7: The Y-7’s dual-mode capability is one of its most powerful features — but knowing when to switch modes is critical for reliable defect detection.

Use AC mode for detecting surface-breaking defects. AC creates a “skin effect” that concentrates the magnetic field at the part surface, making it highly sensitive to tight surface cracks, grinding cracks, and fatigue cracks. AC also provides a slight particle-agitating effect that helps particles migrate to indications.

Use DC mode when you need to detect sub-surface defects or inspect through coatings and paint. DC produces a deeper, more uniform magnetic field that penetrates further into the material — ideal for finding subsurface inclusions, laminations, or defects beneath non-conductive coatings.

Remember: DC yokes require a minimum 40 lb (18 kg) lift force per ASTM E1444, vs. 10 lb for AC. Always verify with a certified yoke test weight (PN 624115) in the appropriate mode before beginning inspection.

Applications

  • Weld inspection on pipelines, pressure vessels, and structural steel
  • Surface and sub-surface defect detection on castings, forgings, and machined parts
  • In-service inspection of aerospace and industrial components
  • Remote field inspections requiring extended cord reach
  • International inspections requiring 230V power compatibility

Specifications

Magnaflux Y-7 AC/DC Yoke – 230V Specifications
Property Specification
SKU 625644
Replaces Part Number 43560
Current Type AC & DC (switchable)
Voltage 230V
Cord Length 12 ft (strain-relieved)
AC Lifting Force Exceeds ASTM E1444 (10 lb / 4.5 kg minimum)
DC Lifting Force Exceeds ASTM E1444 (40 lb / 18 kg minimum)
Construction Sealed, chemical & abrasion resistant
Controls Solid-state, internal
Serialized Yes — individual serial number
Demagnetization No
115V Version Magnaflux Y-7 AC/DC Yoke – 115V
Recommended Accessory Certified Yoke Test Weight (PN 624115)
Brand Magnaflux

Defect location: Surface and subsurface

Ideal for:

  • Field testing
  • Spot inspections
  • In-service inspections
  • Demanding environments
  • Weld inspection

Defect examples:

  • Inclusions
  • Seams
  • Shrink cracks
  • Tears
  • Laps
  • Welding slag
  • Grinding cracks
  • Quenching cracks
  • Fatigue cracks

Specifications

ASME BPVC

ASTM E709

ASTM E1444

ASTM E3024

OPERATION

1. Connect yoke to power supply / battery pack.

2. Y-7 Model Only: Select AC or DC operating mode using switch on back of yoke. WARNING: Do not operate selector switch while yoke is energized.

3. Position yoke legs at right angles to the direction of suspected discontinuities. Adjust legs as needed for best contact with surface.

4. Depress trigger to energize yoke. Apply magnetic particles to area between legs.

a. If using dry powder, blow off excess while yoke is energized to reveal indications.

b. If using fluorescent particles, view surface with UV-A in darkened environment to reveal indications.

5. Evaluate indications for size, shape, and relevant location.

6. Reposition yoke legs at 90-degrees to previous position and repeat steps 4-5 to reveal indications in all directions.

7. Y-6 and Y-7 Models Only: Demagnetize by energizing yoke then slowly withdrawing it from the surface, up to 18 in / 45 cm distance. NOTE: For Y-7 model only, use AC mode for demagnetization.